Intermediate Temperature Cooling Unit
Overview
What you need to judge this in 30 seconds
SBIR · Phase: BOTH · Topic DON27BZ01-NV005 · Solicitation 27.BZ
Navy ships have a chilled water system that runs throughout the ship providing cooling to electronic equipment. Operating at a nominal temperature of 42°F, the chilled water system creates a sizable load on the ship’s electrical plant. The DDG 51 class is approaching available power and cooling capacity limits. Reducing the energy required to provide equivalent cooling capacity would preserve Service Life Allowance (SLA) for future system upgrades. Additionally, having cold water running through pipes throughout the ship creates a risk of water condensing on the piping, which can create electrical hazards inside equipment. While some pieces of equipment are designed to receive chilled water at a specific temperature, other pieces of equipment are more flexible in their cooling requirements. These systems could utilize chilled water that is at a higher temperature, which would require less energy to cool and generate less condensation. Estimates indicate that approximately 200 refrigeration tons (rtons) of cooling could be accomplished by an intermediate temperature cooling loop. This load could be supported by one or more intermediate temperature cooling units. There are no Navy-qualified chillers designed to operate at an intermediate temperature. Work is required to design and qualify a new unit that operates at approximately 65°F, with emphasis on a small footprint. The unit shall include the chiller, circulating pump, piping, instrumentation, and controls. A new unit must meet all applicable Navy standards including shock, noise, vibration, and electromagnetic interference (EMI), as well as reliability and maintainability metrics. Cooling mediums may include but are not limited to water, seawater, or water with glycol additives. For commonality purposes, the equipment shall be galvanically compatible with copper-nickel piping. The proposer shall define performance metrics of the proposed solution to include cooling capacity, energy efficiency, power draw, output pressure, output flow rate, and notional Not-To-Exceed physical dimensions for all equipment.
- Category
- R&D
- Industry
- Needs verification
- Technology
- Needs verification
- Target stage
- Needs verification
- Project duration
- Needs verification
- Estimated preparation
- Needs verification
Funding
Award size and how it is paid
- Award range
- Needs verification
- Currency
- USD
- Total programme budget
- Needs verification
- Support type
- Needs verification
- Co-funding
- Needs verification
- Matching fund
- Needs verification
- Disbursement
- Needs verification
- Note
- -
Eligibility
Can we actually apply?
SBIR/STTR 은 미국 중소기업만 지원할 수 있습니다(Small Business Act 법정 요건). • 계열사를 포함해 상시 종업원 500명 이하 • 미국 시민 또는 영주권자 1인 이상이 50%를 초과해 직접 소유·지배 • 미국 내 사업장을 두고 주로 미국 내에서 사업을 영위할 것 • 수행책임자(PI)의 주된 근무처가 신청 기업일 것 출처: https://www.sbir.gov/faq/eligibility-requirements
- Company age
- Needs verification
- Employees
- 0명 ~ 500명
- Revenue limits
- Needs verification
- Consortium
- Needs verification
Location Requirements
Geography and legal-entity conditions
- Primary country
- 🇺🇸 United States
- Also eligible
- None
- Foreign companies
- No
- Local entity
- Required
- Location condition
- 미국 내 사업장을 두고 미국 시민·영주권자가 50%를 초과해 소유한 중소기업만 신청할 수 있습니다(법정 요건).
Required Documents
Required/optional · issuer · difficulty · validity · cautions
Document requirements were not captured (needs verification). Check the official announcement.
Application Process
How you apply
Application process not captured.
Evaluation
Review process and criteria
Evaluation process not captured.
Timeline
Announcement → intake → review → agreement → execution
Process steps were not captured.
Equity & Financial Terms
Equity, loans and contract conditions
- Equity required
- Needs verification
- Loan
- Non-dilutive grant
- Duplicate funding
- Needs verification
- IP ownership
- Needs verification
- Deliverable ownership
- Needs verification
- Exclusivity
- Needs verification
- Right of first refusal
- Needs verification
- Audit & settlement
- Needs verification
Risk Intelligence
Should we apply at all? — five dimensions plus an overall score (lower is safer)
No risk assessment yet. Re-analyse from Admin.
IP / Idea Protection
How much of your technology and idea you must disclose
No IP assessment yet.
AI Analysis
Pros · cons · difficulty · competition · attractiveness
From paperwork and review stages
Heuristic from award size and type
Amount, terms and IP combined
Weighted average of five dimensions
- Needs verification
- Needs verification
- Nothing flagged
Similar Programs
Comparable by type, country and technology
- DIRECT TO PHASE II: Minimally Invasive Remote Blood Collection Device for Free-Ranging Cetaceans
🇺🇸 United States · R&D program · U.S. Department of War — NAVY
Needs verificationD-14 - Noninvasive Detection and Localization of Occult Hemorrhage
🇺🇸 United States · R&D program · U.S. Department of War — DARPA
Needs verificationD-14 - Scalable Processing of Large Area, Oriented 2-Dimensional Polymer Films
🇺🇸 United States · R&D program · U.S. Department of War — OSD
Needs verificationD-14 - Expeditionary Solar Refinery for Direct Synthesis of Methanol Feedstock from Water and Air
🇺🇸 United States · R&D program · U.S. Department of War — OSD
Needs verificationD-14 - Fuel-Flexible Spacecraft Electric Propulsion System
🇺🇸 United States · R&D program · U.S. Department of War — DARPA
Needs verificationD-14
Source & Provenance
Every value carries its source URL and fetch time
- Official URL
- https://www.dodsbirsttr.mil/topics-app/
- Application URL
- https://www.dodsbirsttr.mil/topics-app/
- Last fetched
- 2026.10.07
- Human review
- Not reviewed — check the official announcement
- First seen
- 2026.10.07
- Data status
- Auto-collected, not reviewed
- AI enrichment
- Needs verification
- PRIMARYSBIR.gov topic — Intermediate Temperature Cooling Unit
Fetched 2h ago
- HTMLSBIR/STTR 자격요건 (법정)
Fetched 2h ago
- HTML발주 기관 공식 공고
Fetched 2h ago
- · 2h ago — 최초 수집 (4d0531bf)